View DDI Temperature Information

About this task

This command displays information for DDI transceivers.

Note

Note

Transceiver support differs across hardware platforms. For information about supported parts, see Extreme Optics website.

Procedure

  1. Enter Privileged EXEC mode:

    enable

  2. View temperatures:

    show pluggable-optical-modules temperature [{slot/port[/sub-port][-slot/port[/sub-port]][,...][slot/all][all]}]

Example

Switch:1#show pluggable-optical-modules temperature

================================================================================
                    Pluggable Optical Module Temperature(C)
================================================================================
PORT         LOW_ALARM LOW_WARN    ACTUAL  HIGH_WARN HIGH_ALARM THRESHOLD
NUM          THRESHOLD THRESHOLD   VALUE   THRESHOLD THRESHOLD  STATUS
--------------------------------------------------------------------------------
1/2             7.0       1.1250   65.2539    0.0       3.0156  Low Alarm
1/3             7.0       1.1250   65.2539    0.0       3.0156  Low Alarm
1/9             7.0625    0.0      65.2539    0.0       3.0156  Low Alarm
1/15            7.0625    0.0      65.2539    0.0       3.0156  Low Alarm
2/1             7.0625    0.0      65.2539    0.0       3.0156  Low Alarm
2/2             7.0625    0.0      65.2539    0.0       3.0156  Low Alarm
2/3             7.0625    0.0      65.2539    0.0       3.0156  Low Alarm

Variable Definitions

Use the data in the following table to use the show pluggable-optical-modules temperature command.

Variable

Value

{slot/port[/sub-port][-slot/port[/sub-port]][,...][slot/all][all]}

Identifies the slot and port in one of the following formats:
  • a single slot and port (slot/port)

  • a range of slots and ports (slot/port-slot/port)

  • a series of slots and ports (slot/port,slot/port,slot/port)

  • all ports on the same slot (slot/all)

  • all ports on the switch (all)

If the platform supports channelization and the port is channelized, you must also specify the sub-port in the format slot/port/sub-port.